{"id":1509,"date":"2020-10-14T15:38:37","date_gmt":"2020-10-14T13:38:37","guid":{"rendered":"http:\/\/dmc.pwr.edu.pl\/?p=1509"},"modified":"2020-10-16T09:32:47","modified_gmt":"2020-10-16T07:32:47","slug":"new-article-in-engineering-failure-analysis","status":"publish","type":"post","link":"https:\/\/dmc.pwr.edu.pl\/index.php\/2020\/10\/14\/new-article-in-engineering-failure-analysis\/","title":{"rendered":"New article in Engineering Failure Analysis"},"content":{"rendered":"\n<div class=\"wp-block-image\"><figure class=\"alignleft is-resized\"><img fetchpriority=\"high\" decoding=\"async\" src=\"http:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/10\/ENGFAILANAL.jpg\" alt=\"\" class=\"wp-image-1512\" width=\"225\" height=\"307\" srcset=\"https:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/10\/ENGFAILANAL.jpg 563w, https:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/10\/ENGFAILANAL-220x300.jpg 220w\" sizes=\"(max-width: 225px) 85vw, 225px\" \/><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"text-align:left\"><p align=\"justify\">We are not slowing down! Another article by Dr Pavlo Krot, and Prof. Rados\u0142aw Zimroz has been recently published in<a href=\"https:\/\/www.journals.elsevier.com\/engineering-failure-analysis\"> Engineering Failure Analysis<\/a> journal. It presents the results of abrupt failure investigation in the structure of industrial plant for hydrostatic pressure testing tubes. <\/p><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"683\" height=\"183\" src=\"http:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/10\/newpostDMC.png\" alt=\"\" class=\"wp-image-1510\" srcset=\"https:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/10\/newpostDMC.png 683w, https:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/10\/newpostDMC-300x80.png 300w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The authors proposed two options of plant modernization to reinforce the structure for safe work under pressure from 70 MPa to 125 MPa depending on the tube size and testing conditions. Such improvements have a significant potential for increasing the testing plant&#8217;s productivity. \n\n<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The work presented in these papers has been funded by the <a href=\"http:\/\/dmc.pwr.edu.pl\/index.php\/preventive-maintenance-system-on-safety-devices-of-mining-machinery-safeme4mine\/\">SAFEME4MINE<\/a> project. Full citations can be found below.<\/p>\n\n\n<div class=\"teachpress_pub_list\"><form name=\"tppublistform\" method=\"get\"><a name=\"tppubs\" id=\"tppubs\"><\/a><\/form><table class=\"teachpress_publication_list\"><tr class=\"tp_publication tp_publication_article\"><td class=\"tp_pub_info\"><p class=\"tp_pub_author\"> Krot, Pavlo;  Zimroz, Radoslaw<\/p><p class=\"tp_pub_title\"><a class=\"tp_title_link\" onclick=\"teachpress_pub_showhide('65','tp_links')\" style=\"cursor:pointer;\">Failure analysis and modernization of high-pressure hydraulic press for drilling tubes testing<\/a> <span class=\"tp_pub_type tp_  article\">Journal Article<\/span> <\/p><p class=\"tp_pub_additional\"><span class=\"tp_pub_additional_in\">In: <\/span><span class=\"tp_pub_additional_journal\">Engineering Failure Analysis, <\/span><span class=\"tp_pub_additional_volume\">vol. 117, <\/span><span class=\"tp_pub_additional_pages\">pp. 104772, <\/span><span class=\"tp_pub_additional_year\">2020<\/span>.<\/p><p class=\"tp_pub_menu\"><span class=\"tp_resource_link\"><a id=\"tp_links_sh_65\" class=\"tp_show\" onclick=\"teachpress_pub_showhide('65','tp_links')\" title=\"Show links and resources\" style=\"cursor:pointer;\">Links<\/a><\/span><\/p><div class=\"tp_bibtex\" id=\"tp_bibtex_65\" style=\"display:none;\"><div class=\"tp_bibtex_entry\"><pre>@article{Krot2020c,<br \/>\r\ntitle = {Failure analysis and modernization of high-pressure hydraulic press for drilling tubes testing},<br \/>\r\nauthor = {Pavlo Krot and Radoslaw Zimroz},<br \/>\r\nurl = {https:\/\/doi.org\/10.1016\/j.engfailanal.2020.104772},<br \/>\r\ndoi = {10.1016\/j.engfailanal.2020.104772},<br \/>\r\nyear  = {2020},<br \/>\r\ndate = {2020-01-01},<br \/>\r\njournal = {Engineering Failure Analysis},<br \/>\r\nvolume = {117},<br \/>\r\npages = {104772},<br \/>\r\npublisher = {Elsevier BV},<br \/>\r\nkeywords = {},<br \/>\r\npubstate = {published},<br \/>\r\ntppubtype = {article}<br \/>\r\n}<br \/>\r\n<\/pre><\/div><p class=\"tp_close_menu\"><a class=\"tp_close\" onclick=\"teachpress_pub_showhide('65','tp_bibtex')\">Close<\/a><\/p><\/div><div class=\"tp_links\" id=\"tp_links_65\" style=\"display:none;\"><div class=\"tp_links_entry\"><ul class=\"tp_pub_list\"><li><i class=\"fas fa-globe\"><\/i><a class=\"tp_pub_list\" href=\"https:\/\/doi.org\/10.1016\/j.engfailanal.2020.104772\" title=\"https:\/\/doi.org\/10.1016\/j.engfailanal.2020.104772\" target=\"_blank\">https:\/\/doi.org\/10.1016\/j.engfailanal.2020.104772<\/a><\/li><li><i class=\"ai ai-doi\"><\/i><a class=\"tp_pub_list\" href=\"https:\/\/dx.doi.org\/10.1016\/j.engfailanal.2020.104772\" title=\"Follow DOI:10.1016\/j.engfailanal.2020.104772\" target=\"_blank\">doi:10.1016\/j.engfailanal.2020.104772<\/a><\/li><\/ul><\/div><p class=\"tp_close_menu\"><a class=\"tp_close\" onclick=\"teachpress_pub_showhide('65','tp_links')\">Close<\/a><\/p><\/div><\/td><\/tr><\/table><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignright is-resized\"><img decoding=\"async\" src=\"http:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/08\/safe-1.png\" alt=\"\" class=\"wp-image-1334\" width=\"208\" height=\"166\" srcset=\"https:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/08\/safe-1.png 1023w, https:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/08\/safe-1-300x239.png 300w, https:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/08\/safe-1-768x613.png 768w\" sizes=\"(max-width: 208px) 85vw, 208px\" \/><\/figure><\/div>\n\n\n\n<figure class=\"wp-block-image is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/09\/EIT_LOGO_2-768x433.png\" alt=\"\" class=\"wp-image-1426\" width=\"313\" height=\"176\" srcset=\"https:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/09\/EIT_LOGO_2-768x433.png 768w, https:\/\/dmc.pwr.edu.pl\/wp-content\/uploads\/2020\/09\/EIT_LOGO_2-768x433-300x169.png 300w\" sizes=\"(max-width: 313px) 85vw, 313px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>We are not slowing down! Another article by Dr Pavlo Krot, and Prof. Rados\u0142aw Zimroz has been recently published in Engineering Failure Analysis journal. It presents the results of abrupt failure investigation in the structure of industrial plant for hydrostatic pressure testing tubes. The authors proposed two options of plant modernization to reinforce the structure &hellip; <a href=\"https:\/\/dmc.pwr.edu.pl\/index.php\/2020\/10\/14\/new-article-in-engineering-failure-analysis\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;New article in Engineering Failure Analysis&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"aside","meta":{"ngg_post_thumbnail":0,"footnotes":""},"categories":[1],"tags":[11],"class_list":["post-1509","post","type-post","status-publish","format-aside","hentry","category-bez-kategorii","tag-safeme4mine","post_format-post-format-aside"],"_links":{"self":[{"href":"https:\/\/dmc.pwr.edu.pl\/index.php\/wp-json\/wp\/v2\/posts\/1509","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dmc.pwr.edu.pl\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dmc.pwr.edu.pl\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dmc.pwr.edu.pl\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dmc.pwr.edu.pl\/index.php\/wp-json\/wp\/v2\/comments?post=1509"}],"version-history":[{"count":11,"href":"https:\/\/dmc.pwr.edu.pl\/index.php\/wp-json\/wp\/v2\/posts\/1509\/revisions"}],"predecessor-version":[{"id":1527,"href":"https:\/\/dmc.pwr.edu.pl\/index.php\/wp-json\/wp\/v2\/posts\/1509\/revisions\/1527"}],"wp:attachment":[{"href":"https:\/\/dmc.pwr.edu.pl\/index.php\/wp-json\/wp\/v2\/media?parent=1509"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dmc.pwr.edu.pl\/index.php\/wp-json\/wp\/v2\/categories?post=1509"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dmc.pwr.edu.pl\/index.php\/wp-json\/wp\/v2\/tags?post=1509"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}